Interfacing and Using the Isolated Logic
Inputs
The IM483 has 4 optically isolated logic inputs which are located on connector
P1. These inputs are isolated to minimize or eliminate electrical noise coupled
onto the drive control signals. Each input is internally pulled-up to the level of
the optocoupler supply and may be connected to sinking outputs on a controller
such as the IMS LYNX or a PLC. These inputs are:
1] Step Clock (P1:2)
2] Direction (P1:3)
3] Enable (P1:5)
4] Reset (P1:6)
Of these inputs only step clock and direction are required to operate the
IM483.
The schematic shown in Figure 7.5 illustrates the inputs.
HP-2630
HP-2630
HP-2630
HP-2630
470
470
470
470
Optocoupler Supply P1:4
+5VDC
Step Clock P1:2
CW/CCW Direction P1:3
Enable/Disable P1:5
Reset P1:6
Figure 7.5: Optically Isolated Inputs