52
Symptom
Motor stalls during acceleration.
Possible Problem
Incorrect current adjust setting or resistor value.
Motor is undersized for application.
Acceleration on controller is set too high.
Power supply voltage too low.
Symptom
Excessive motor and driver heating.
Possible Problem
Inadequate heat sinking / cooling.
Current reduction not being utilized.
Current set too high.
Symptom
Inadequate holding torque.
Possible Problem
Incorrect current adjust setting or resistor value.
Increase holding current with the current reduction adjust resistor.